The final technique for simplifying the modeling of radials caught me by surprise. It consists of using the facility in NEC that allows 2 ground qualities--a set radius for an inner set of values, and from that point onward, some other values. The reasoning goes that a set of radials in effect improves the ground quality. Therefore, setting the inner radius to the length of the radial system at a high conductivity value, with a lesser value from that point outward, would largely replicate the effect of a radial system without requiring the modeling of radials.
Since the practice has some currency in various quarters, it deserves an examination, even if we know in advance that the interaction of buried radial systems is quite different from a simple soil quality improvement. We need to see to what degree the modeling technique yields something useful, even by way of indicators of antenna performance. To this end, let's go back to the very beginning of our work in this series and take a further look at the classic 1/4 wavelength monopole.
Table 1. Soil types used in the study Soil Type Conductivity Permittivity Siemans/meter dielectric constant Very Poor 0.001 5 Poor 0.002 13 Good (Average) 0.005 13 Very Good 0.0303 20
Table 2. 40-m vertical monopole, 25 mm diameter; 40.96-m (0.25 wavelength) radials, 2 mm diameter, tapered segmentation: 0.001 to 0.04 wavelength per wire; radials 0.001 wavelength below ground; NEC-4. Soil Type Gain TO Angle Source Impedance dBi degrees R +/- J X Ohms 4-radials: 32 wires; 62 segments Very Poor -4.37 27 87.04 + j 25.31 Poor -2.49 25 72.45 + j 19.47 Good -0.71 23 60.96 + j 20.42 Very Good 2.10 17 47.34 + j 14.52 8-radials: 56 wires; 110 segments Very Poor -3.11 28 65.90 + j 18.09 Poor -1.51 25 58.63 + j 15.18 Good -0.04 23 52.43 + j 15.94 Very Good 2.60 17 44.34 + j 12.60 16-radials: 104 wires; 206 segments Very Poor -1.61 28 52.71 + j 12.43 Poor -0.16 25 49.71 + j 12.18 Good 0.86 23 46.79 + j 12.83 Very Good 2.79 16 42.20 + j 11.18 32-radials: 200 wires; 398 segments Very Poor -1.32 27 44.89 + j 7.54 Poor 0.17 25 43.44 + j 9.55 Good 1.12 22 42.67 + j 10.46 Very Good 2.94 17 40.48 + j 10.03 64-radials: 392 wires; 782 segments Very Poor -1.19 27 40.68 + j 4.11 Poor 0.32 25 39.43 + j 7.08 Good 1.26 22 39.73 + j 8.50 Very Good 3.05 17 39.06 + j 9.07 128-radials: 776 wires; 1550 segments Very Poor -1.12 28 38.60 + j 2.18 Poor 0.17 25 37.32 + j 5.29 Good 1.03 23 37.91 + j 6.99 Very Good 2.87 17 37.94 + j 8.27
Table 2 reviews the modeled values in NEC-4 of a 25-mm diameter monopole over various size radial systems and soil qualities, when the 2-mm diameter radials are buried 0.001 Wavelength below ground (about 6.5" at 1.83 MHz, our test frequency). To consolidate the numbers in a different way, Fig. 1 graphs the gain in dBi of the monopoles, with each line representing a different soil quality and the individual lines tracing the numbers of radials from 4 to 128. The largest differentials appear in the region from 4 to 16 radials and over the poorest soils. We should not neglect the actual numbers for the gain values.
Fig. 2 provides comparable curves for the source resistance calculated by NEC-4 for each of the cases graphed for gain in Fig. 1. As we would expect, the highest values of source resistance and the greatest rates of change occur when the radials are few and the soil is less than of Good quality.
We have also looked at the type of model that uses no radials, but connects the 1/4 Wavelength monopole directly to ground. In earlier examinations, we looked only at the use of the MININEC ground. In Table 3 are values for direct connection to both the MININEC and the Sommerfeld-Norton ground in NEC-4. (The values for a NEC-2 ground may differ, since there is a distinct difference in the treatment of wire approaching and touching ground in the two system. NEC-2 does not permit buried wires, although NEC-4 handles buried wires routinely so long as certain modeling conventions are met.) Fig. 3 graphs the pair of gain curves that result from one soil quality to the next. The NEC-4 S-N curve roughly tracks the values from the 4-radial portion of Table 2. However, the MININEC curve reaches values not achieved by even the 64- and 128-radial portions of Table 2.
Table 3. Direct Connection Values: 40-m vertical monopole, 25 mm diameter, direct connection to ground (no radials), fed at the lowest segment; NEC-4. Soil Type Gain TO Angle Source Impedance dBi degrees R +/- J X Ohms A. MININEC ground Perfect 37.08 + j 6.12 Very Poor -1.00 27 Poor 0.31 25 Good 1.41 23 Very Good 3.16 17 B. Sommerfeld-Norton ground Very Poor -2.26 27 49.32 + j 8.11 Poor -0.89 25 48.78 + j 10.52 Good 0.31 22 47.65 + j 11.48 Very Good 2.48 17 43.36 + j 10.21
The technique that we shall try to compare to these modeled results appears in Fig. 4. We set the monopole touching ground. Beneath the antenna and for a radius of 1/4 Wavelength (40.96 m), we set the soil quality to some higher value. In these tests, we shall use a conductivity of about 0.03 S/m, corresponding to Very Good soil. From that radius outward, we shall use Very Poor soil for the contrast.
Theoretically, NEC calculates the source impedance and currents from the inner radius soil quality, and would do so even had we specified the dividing boundary radius as zero. The far field is calculated using the second or outer ground quality. For the sake of this test, I used EZNEC Pro, which permitted runs using either NEC-2 or NEC-4 and gave access to the MININEC ground as well as to the standard NEC grounds (the high accuracy Sommerfeld-Norton ground calculation system and the "fast" or reflection coefficient calculation system). The results appear in Table 4.
Table 4. Direct Connection Values: 40-m vertical monopole, 25 mm diameter, direct connection to ground (no radials), fed at the lowest segment; dual ground: inner to 40.96 m Very Good, outer Very Poor. Ground System Gain TO Angle Source Impedance dBi degrees R +/- J X Ohms A. MININEC Ground NEC-4 3.16 27 37.08 + j 6.12 NEC-2 1.89 29 37.08 + j 6.12 B. "Fast" NEC Ground NEC-4 2.12 29 35.14 + j 5.37 NEC-2 -5.07 29 179.5 - j 163.0 C. Sommmerfeld-Norton NEC Ground NEC-4 1.21 29 43.36 + j 10.21 NEC-2 0.04 29 56.79 + j 9.58The values shown for the NEC-2 ground calculation systems are in the table largely for reference. They are not considered usable by most modeling software experts. Tradition has used the MININEC ground as a basis for simplified modeling. However, the gain figures for both cores using a MININEC ground exceed the highest value of far-field gain found in Table 2 for all but Very Good Soil. Note that the far-field gain is supposed to be a function of the outer soil quality, which was set at Very Poor. As well, the dual ground quality system of modeling does nothing to correct the fact that MININEC ground forces the source impedance to be calculated over perfect ground. At best, the Sommerfeld-Norton ground using NEC-4 yields values of gain and source impedance similar to those for Good soil and 32 buried radials (from Table 2). However, there is a significant difference in the calculated take-off angle for the two models.
With respect to the simple 1/4 Wavelength monopole, at least, there is nothing in the data calculations to suggest that a dual ground system in any way provides usable data as a substitute for a buried radial system of any size. Since the closest correlation appeared in a NEC-4 S-N run, which presumes that one has NEC-4 at hand, one might as well model the buried radials in the first place.
Because we wish to discover if there is a usable correlation between a dual ground quality system and a buried radial system, I extended the analysis of the array over buried radials. The 1/4 Wavelength length radial systems for the individual elements intersect--how many times being dependent on the number of radials in each system. I used 4, 8, 16, and 32 radials per element, and the resulting radial systems are sketched in Fig. 6.
The results of the model runs appear in Table 5, which provides values for each of our soil qualities for each level of radial system. Fig. 7 provides curves for the gain values, where each line represents a different size radial system. The curves are unexceptional. We should note that the gain barely reaches 5.3 dBi with 32 radials per element over Very Good soil.
Table 5. 2-element parasitic array: driver = 40-m vertical monopole, 25 mm diameter; reflector = sloping 2-mm guy, 40.4 m long; intersecting 40.96-m (0.25 wavelength) radial system, 2 mm diameter, 0.001 wavelength below ground, uniform segmentation; NEC-4. Soil Type Gain TO Angle Front-to Back Source Impedance dBi degrees Ratio dB R +/- J X Ohms 4 Radials per element Very Poor -3.03 28 5.89 102.8 + j 53.58 Poor -1.17 26 6.14 86.89 + j 44.75 Good 0.88 23 7.04 75.31 + j 47.33 Very Good 4.03 17 8.84 62.11 + j 46.58 8 Radials per element Very Poor -1.20 29 7.58 82.12 + j 50.16 Poor 0.29 26 7.96 73.99 + j 45.63 Good 1.94 23 8.62 68.17 + j 47.52 Very Good 4.54 17 9.73 59.75 + j 47.78 16 Radials per element Very Poor 0.25 29 9.40 67.75 + j 49.90 Poor 1.49 26 9.54 65.74 + j 48.23 Good 2.77 23 9.96 63.06 + j 48.75 Very Good 4.95 18 10.54 57.70 + j 48.95 32 Radials per element Very Poor 1.18 29 10.43 60.03 + j 48.96 Poor 2.34 27 10.61 59.34 + j 49.10 Good 3.40 23 11.04 58.66 + j 49.77 Very Good 5.29 17 11.26 55.72 + j 50.06
Fig. 8 graphs in a similar way the modeled front-to-back ratios achieved by the array variations. The 4-radial-per-element system benefits most from soil quality improvements. However, even over Very Good soil, the model does not achieve an 11.3 dB front-to-back ratio.
If we use a direct connection to ground and no radials, the calculated numbers derived from NEC diverge from those yielded by the buried radial systems. Table 6 gives the modeling results of placing the two elements alone over the range of available grounds, including the MININEC ground, the "fast" NEC ground, and the S-N ground. Once more, the latter two are for reference and the general advice not to use these grounds for such purposes remains applicable.
Fig. 9 graphs the gain values for the three sets of NEC-4 runs. Interestingly, the reflection coefficient ground in NEC-4 correlates very well to the MININEC ground. The S-N ground, when used in NEC-4 provides values that coincide roughly with a 12-radial-per- element system, if one can interpolate fairly from the data in Table 5.
The correspondence in gain figures between the MININEC ground and the "fast" ground in NEC-4 disappears if we move to the front-to-back column. See Fig. 10. Although the "fast" ground curve is roughly congruent with the MININEC curve, the "fast" ground values are 5 dB lower. The S-N ground curve is much shallower, but the values are high, even when compared to the front-to-back values for the 32-radial-per-element buried radial system model.
Table 6. 2-element parasitic array: driver = 40-m vertical monopole, 25 mm diameter; reflector = sloping 2-mm guy, 40.4 m long; direct connection to ground (no radials); NEC-4. Soil Type Gain TO Angle Front-to Back Source Impedance dBi degrees Ratio dB R +/- J X Ohms A. MININEC ground Very Poor 2.00 30 11.36 40.19 + j 53.02* Poor 3.34 26 14.25 *MININEC Impedance Good 4.62 24 17.11 is over perfect Very Good 6.36 18 19.50 ground. B. "Fast" NEC Ground Very Poor 2.27 28 6.37 50.40 + j 29.73 Poor 3.50 26 8.63 50.14 + j 36.48 Good 4.67 23 10.82 51.25 + j 42.49 Very Good 6.35 18 14.66 46.64 + j 49.99 C. Sommmerfeld-Norton NEC Ground Very Poor -0.63 29 10.31 69.16 + j 38.46 Poor 0.85 26 10.78 65.61 + j 42.24 Good 2.35 23 11.81 62.44 + j 45.83 Very Good 4.82 18 13.44 53.33 + j 48.39 Note: Use of NEC-2 and the S-N ground will yield reports that differ considerably from the values produced by NEC-4. The following listing is simply to display the differential: D. Sommmerfeld-Norton NEC Ground--NEC-2 Very Poor -11.0 28 0.58 342.3 - j 169.9 Poor -7.06 26 1.46 180.3 - j 77.60 Good -3.60 23 3.55 122.5 + j 4.20 Very Good 2.94 18 10.16 61.57 + j 38.79
Table 6 provides S-N ground data for NEC-2, the version used by most hams. Once more, there is a very large difference in the values reported from yielded by NEC-4 under identical modeling parameter conditions. The values would hardly be useful as anything but artifacts. However, the remaining numbers in Table 6 have equally misleading data values and should also be set aside if one is modeling a buried radial system attached to the array in question.
The final step in our test is whether using a dual soil-quality system fairs any better than the simple MININEC ground. To examine this question, I altered the model to include Very Good ground under the antenna and Very Poor ground at a distance. Since the model involves radial systems that intersect, with about 1/8 Wavelength between element bases, I chose a radius of 3/8 Wavelength for the inner ground quality (61.43 m at 1.83 MHz). The results of the modeling appear in Table 7.
Table 7. 2-element parasitic array: driver = 40-m vertical monopole, 25 mm diameter; reflector = sloping 2-mm guy, 40.4 m long; direct connection to ground (no radials), fed at the lowest segment; dual ground: inner to 61.43 m (3/8 Wavelength from array center line) Very Good, outer Very Poor. Ground System Gain TO Angle Front-to Back Source Impedance dBi degrees Ratio dB R +/- J X Ohms A. MININEC Ground NEC-4 6.36 18 19.50 40.19 + j 53.02 NEC-2 6.82 11 18.58 40.21 + j 53.02 B. "Fast" NEC Ground NEC-4 6.03 25 14.43 46.64 + j 49.99 NEC-2 No usable values C. Sommmerfeld-Norton NEC Ground NEC-4 4.45 25 14.04 53.33 + j 48.39 NEC-2 3.51 11 9.58 61.57 + j 38.79Using the normal MININEC ground for the exercise produced excessively high values of gain and front-to-back ratio relative to the buried-radial models--in both NEC-4 and NEC-2. As well, NEC-2 depressed the TO angle by 7 degrees relative to any other report. Although the "fast" and S-N numbers are provided, once more they are no more than reference reports. The end result, however, is that the dual-ground system provides no usable data or even indicators of data for the array in question.
As expected, the dual-ground modeling technique can be as misleading as any other substitute for a direct and detailed model of a buried radial system. The calculations for the way in which radials intersect with a given soil quality when buried is quite different from the calculations for the soil alone. As a result, a radial system is not equivalent with respect to antenna performance to a simple improvement of the soil quality.
Thinking of a radial system as an improvement in soil quality may have some utility when the concern is the overall RF ground for a station and its antenna(s). However, that mode of thought can be highly misleading when it comes to calculations that yield potential antenna performance figures. We have looked in review at the results for the standard techniques of simplifying models by placing them without radials over a MININEC ground, and the result is simply that both systems of simplification are equally but separately misleading. The only type of modeling that seems adequate to a buried radial system is a buried radial model. Any suggested simplification would require that we first test the simplified model against a full model with all buried radials modeled. If a reliable correlation appears--and it might, as illustrated in Part 4--then we can use the simplification. However, once we have the full model, the rationale for simplifying seems largely to disappear.
As one step in the direction of developing more adequate models of vertical antennas and arrays for 160 meters (or any other band, for that matter), this series has tried to set forth some basics of the varied results that different kinds of models produce, as well as to give some perspective on the divergence in reports yielded by the range of ground qualities that we can model. If any theme emerges from these notes, it should be this: to the degree possible, let us model accurately and without shortcut every possible aspect of a 160-meter vertical antenna or array and begin from the ground up.
Updated 09-25-01. © L. B. Cebik, W4RNL. This item originally appeared in The National Contest Journal (Sep/Oct, 2001), pp. 4-9. Data may be used for personal purposes, but may not be reproduced for publication in print or any other medium without permission of the author.